Drugs of Abuse Array I Plus Quality Control
A comprehensive quality control designed for use in the routine monitoring of 14 drugs of abuse on Randox Biochip systems. Two levels of control are provided covering the cut-off range.
Features & Benefits
- Lyophilised for enhanced stability
- Stable to expiry date at 2oC – 8oC
- Urine- Reconstituted stability of 14 days at 2oC – 8oC
- Whole Blood – Reconstituted stability of 7 days at 2oC – 8oC or 14 days at -20oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Drugs of Abuse Array 1 Plus (Urine) Controls | 2 x 4 x 1 ml | 14 | EV3745 | |
Drugs of Abuse Array 1 Plus (Whole Blood) Controls | 2 x 4 x 1 ml | 14 | EV3750 | |
Analytes
- Amphetamine
- Barbiturates
- Benzodiazepine 1
- Benzodiazepine 2
- Buprenorphine
- Cannabinoids
- Cocaine Metabolite
- MDMA
- Methadone
- Methamphetamine
- Opiates
- Phencyclidine
- Tricyclic Antidepressants
- Creatinine (only available in Urine – EV3745)
Related Products
Therapeutic Drug Quality Control
The Randox Acusera Therapeutic Drug Quality Control covers an extensive range of 18 drugs including commonly used antibiotics, anti-convulsants, anti-inflammatory and anti-cancer drugs. As an assayed control instrument and method specific target values and ranges are provided for the most common instruments and methods. A reconstituted stability of 4 weeks at 2°C – 8°C significantly minimises waste and helps to reduce costs.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human material
- Assayed target values provided for 18 parameters
- Three levels available covering therapeutic and toxic ranges
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 4weeks at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Therapeutic Drug Control Level 1 | 20 x 5ml | 18 | HD1667 | |
Therapeutic Drug Control Level 2 | 20 x 5ml | 18 | HD1668 | |
Therapeutic Drug Control Level 3 | 20 x 5ml | 18 | HD1669 | |
Analytes
- Amikacin
- Caffeine
- Carbamazepine
- Cyclosporin
- Digoxin
- Ethosuximide
- Gentamicin
- Lithium
- Methotrexate
- Paracetamol
- Phenobarbital
- Phenytoin
- Primidone
- Salicylate
- Theophylline
- Tobramycin
- Valproic Acid
- Vancomycin
Lipoprotein (a) Quality Control
The Randox Acusera Lipoprotein (a) quality control is designed for use in the routine monitoring of immunoturbidimetric Lp (a) assays. A reconstituted stability of 14 days at 2°C – 8°C significantly minimises waste and helps to reduce costs.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Assayed target values provided
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 14 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Lipoprotein (a) Control Level 3 | 3 x 1ml | 1 | LP3406 | |
Analytes
- Lipoprotein (a)
Related Products
Apolipoprotein Quality Control
The Randox Acusera Apolipoprotein quality control is designed for use in the routine monitoring of 4 specialised Apolipoprotein assays. Assayed method specific target values and ranges are provided.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Assayed target values provided for 4 specialised Apolipoproteins
- Three levels available covering low, borderline and high risk levels
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 7 days at 2°C – 8°C for Apolipoprotein A-II and Apolipoprotein C-II, Apolipoprotein E is stable for 8 hours at 2°C – 8°C. All analytes are stable for 4 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Apolipoprotein Control Level 1 | 3 x 1ml | 4 | LE5016 | |
Apolipoprotein Control Level 2 | 3 x 1ml | 4 | LE5017 | |
Apolipoprotein Control Level 3 | 3 x 1ml | 4 | LE5018 | |
Analytes
- Apolipoprotein A-1
- Apolipoprotein C-III
- Apolipoprotein C-II
- Apolipoprotein E
Related Products
Lipid Quality Control
The Randox Acusera Lipid quality control includes assayed method specific target values and ranges for 7 analytes covering the complete lipid profile. Unlike many manufacturers material the Randox lipid control does not contain preservatives such as Sodium Azide which can interfere with clearance methods of HDL and LDL determination. Two flexible and convenient pack sizes are also available to suit all laboratory sizes.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Assayed target values provided for 6 parameters
- Three levels available covering low, borderline and high risk levels
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 7 days at 2°C – 8°C or 4 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Lipid Control Level 1 | 5 x 1ml | 7 | LE2668 | |
Lipid Control Level 2 | 5 x 1ml | 7 | LE2669 | |
Lipid Control Level 3 | 5 x 1ml | 7 | LE2670 | |
Lipid Control Level 1 | 5 x 3ml | 7 | LE2661 | |
Lipid Control Level 2 | 5 x 3ml | 7 | LE2662 | |
Lipid Control Level 3 | 5 x 3ml | 7 | LE2663 | |
Analytes
- Apolipoprotein A-1
- Apolipoprotein B
- HDL Cholesterol
- LDL Cholesterol
- Lipoprotein (a)
- Total Cholesterol
- Triglycerides
Cystatin C Quality Control
Dedicated Cystatin C control designed for use in the routine monitoring of both accuracy and precision. Supplied in a convenient, liquid ready-to-use format, no preparation is required. Assayed target values and ranges are provided for this true third party control.
Features & Benefits
- Liquid ready-to-use
- 100% human serum
- Assayed target values provided
- Stable to expiry date at 2°C – 8°C
- Open vial stability of 30 days at 2°C – 8°C
- Multi-point calibrator available
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Cystatin C Control Level 2 | 3 x 2ml | 1 | CYS10446 | |
Cystatin C Control Level 3 | 3 x 2ml | 1 | CYS10447 | |
Analytes
- Cystatin C
Related Products
High Sensitivity CRP Quality Control
The Randox Acusera High Sensitivity CRP quality control is designed to monitor the performance of high sensitivity CRP assays. The liquid ready-to-use format makes it convenient and easy to use. Once opened the control is stable to expiry at +2-8°C significantly minimising waste and helping to reduce costs.
Features & Benefits
- Liquid ready-to-use
- 100% human serum
- Assayed target values provided
- Stable to expiry date at 2°C – 8°C
- Once opened stable to expiry date at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
High Sensitivity CRP Control Level 1 | 10 x 1ml | 1 | CP2476 | |
High Sensitivity CRP Control Level 2 | 10 x 1ml | 1 | CP2477 | |
Analytes
- CRP
Related Products
CRP Quality Control
The Randox Acusera CRP quality control is designed to monitor the performance of traditional CRP assays. The liquid ready-to-use format makes it convenient and easy to use. Once opened the control is stable for 30 days at +2-8°C significantly minimising waste and helping to reduce costs.
Features & Benefits
- Liquid ready-to-use
- 100% human serum
- Assayed target values provided
- Stable for 30 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Liquid CRP Control Level 2 | 10 x 1ml | 1 | CP2480 | |
Liquid CRP Control Level 3 | 10 x 1ml | 1 | CP2481 | |
Analytes
- CRP
Related Products
CSF Quality Control
The Randox Acusera cerebrospinal fluid quality control is designed for use in the routine monitoring of both accuracy and precision on a wide range of instruments. Assayed method specific target values and ranges are provided for 11 parameters including percentage total protein quoted for electrophoresis regions at Albumin, Alpha-1-Globulin, Alpha-2-Globulin, Beta Globulin and Gamma Globulin.
Features & Benefits
- Lyophilised for enhanced stability
- Human based material
- Assayed target values provided for 11 parameters
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 14 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
CSF Control Level 2 | 10 x 3ml | 11 | CF1500 | |
CSF Control Level 3 | 10 x 3ml | 11 | CF1501 | |
Analytes
- Albumin (electrophoresis)*
- Alpha – 1- globulin (electrophoresis)*
- Alpha – 2- globulin (electrophoresis)*
- Beta- globulin (electrophoresis)*
- Chloride
- Gamma – globulin (electrophoresis)*
- Glucose
- Immunoglobulin G (IgG)
- Lactate
- Protein (Total)
- Sodium
*No claims are made regarding values or stability
Specific Protein Quality Control
The Randox Acusera Specific Protein quality control covers 26 serum proteins including immunoglobulins, complement proteins and inflammatory proteins. Designed for use in the routine monitoring of both accuracy and precision, assayed target values and ranges are provided for both immunoturbidimetric and nephelometric based methods. The liquid ready-to-use format is not only convenient and easy to use but eliminates the possibility of reconstitution errors.
Features & Benefits
- Liquid ready-to-use
- 100% human serum
- Assayed target values provided for 26 analytes
- Contains Total & Free Lambda Light Chains and Total Kappa Light chains
- Stable to expiry date at 2°C – 8°C
- Open vial stability of 30 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Specific Protein Control Level 1 | 3 x 1 ml | 26 | PS2682 | |
Specific Protein Control Level 2 | 3 x 1 ml | 26 | PS2683 | |
Specific Protein Control Level 3 | 3 x 1 ml | 26 | PS2684 | |
Specific Protein Control Level 1 | 6 x 3 ml | 26 | PS10221 | |
Specific Protein Control Level 2 | 6 x 3 ml | 26 | PS10222 | |
Specific Protein Control Level 3 | 6 x 3 ml | 26 | PS10223 | |
Analytes
- AFP
- Albumin
- a-1-Antitrypsin
- a-1-Acid Glycoprotein
- a-2-Macroglobulin
- ASO
- Anti-thrombin III
- b-2-Microglobulin
- Ceruloplasmin
- Complement C3
- Complement C4
- CRP
- Haptoglobin
- IgA
- IgE
- IgG
- IgM
- Kappa Light Chain
- Lambda Light Chain
- Lambda Light Chain (Free)*
- Prealbumin (Transthyretin)
- Serum Ferritin
- RF
- RBP
- Total Protein
- Transferrin
*Not for use in USA