RIQAS Point of Care EQA
RIQAS Point of Care EQA
Designed to improve the quality of Point of Care Testing (POCT) in locations such as pharmacies, GP surgeries, hospital out patient departments, sports clinics, supermarkets, diagnostic/treatment and walk-in centres.
RIQAS Point of Care EQA provides independent evidence of the accuracy and reliability of test results.
Why RIQAS Point of Care?
Programme Offering
Tests
Role
Matrix
Learn More
Lipids (Total Cholesterol & HDL Cholesterol)*
- Risk Factor for heart Disease
- Monitoring lipid lowering therapy
Whole Blood
HbA1c (Glycated Hemoglobin)*
- Diagnosing diabetes mellitus
- Monitoring treatment
- Encouraging self-management
Whole Blood
CRP (C Reactive Protein)*
- Early detection of infectious disease
- Identifying need for antibiotic treatment
Whole Blood
Glucose / Ketones
- Diagnose and monitor diabetes
- Monitor the presence of hypoglycemia (low blood glucose) and hyperglycemia (high blood glucose)
- To determine whether excessive ketones are present in the blood, to detect diabetic ketoacidosis (DKA)
Serum
Key Cycle Dates
RQ9181 Distribution Month Sample Distributed Result Submission Deadline January 2024 8th January 17th January February 2024 5th February 14th February March 2024 4th March 13th March April 2024 2nd April 10th April May 2024 6th May 15th May June 2024 3rd June 12th June July 2024 1st July 10th July August 2024 5th August 14th August September 2024 2nd September 11th September October 2024 7th October 16th October November 2024 4th November 13th November December 2024 2nd December 11th December What Participants Say
What participants say
Our unrivalled commitment to quality and service ensures high levels of customer satisfaction, this is evident from the responses to our latest customer satisfaction survey:
“All in all a quick and efficient service”
“Good online system”
“Very helpful team”
“Excellent training”
“They are an experienced team”
“Very satisfied with the service that we receive”
“Very good value for money”
“The website is great”
The Importance of Quality Assurance
Importance of quality assurance
Quality assurance is an essential aspect of any clinical/diagnostic testing service and is aimed at ensuring the accuracy and reliability of patients’ results. The right result allows the right clinical advice to be offered in a timely manner. Quality assurance operates at two levels:Internal Quality Control
Internal Quality Control includes operator training/ competency assessment, analyser/ test system maintenance, and adherence to policies/ processes. Whilst some point of care analysers include inbuilt quality checks, cross-check analysis against samples with known levels provides immediate assurance and evidence that a patient’s result is safe to report.External Quality Assessment
External Quality Assessment involves analysis of samples with unknown levels that have been distributed by an external organisation. Participants are informed how their results compare with other participants, hence providing independent evidence of performance. Increasingly, participation in an external quality assessment scheme is becoming a mandatory requirement where health and healthcare services are being provided.
EQA provides assurance to both staff and customers that testing provides accurate and reliable results.
Want to know more?
Contact us or download the RIQAS Point of Care catalogue to learn more.
Continue Reading
Frequently Asked Questions
RIQAS
Contact Us
RIQAS Point of Care EQA
Designed to improve the quality of Point of Care Testing (POCT) in locations such as pharmacies, GP surgeries, hospital out patient departments, sports clinics, supermarkets, diagnostic/treatment and walk-in centres, RIQAS Point of Care EQA provides independent evidence of the accuracy and reliability of test results. Randox International Quality Assessment Scheme (RIQAS) is the world’s largest EQA scheme with over 55,000 participants in more than 134 countries.
Why RIQAS Point of Care?
About RIQAS Point of Care
How it Works
Tests and Analysers
Test Role Matrix Lipids (Total Cholesterol & HDL Cholesterol) • Risk factors for heart disease
• Monitoring lipid lowering therapy
Whole Blood HbA1c (Glycated Haemoglobin) • Diagnosing diabetes mellitus
• Monitoring treatment
• Encouraging self-management
Whole Blood C-Reactive Protein (CRP) • Early detection of infectious disease
• Identifying need for antibiotic treatment
Whole Blood Glucose/Ketones • Diagnose and monitor diabetes
• Monitor for the presence of hypoglycaemia
(low blood glucose) and hyperglycaemia (high blood glucose)
• To determine whether excessive ketones are present in the blood, to detect diabetic ketoacidosis (DKA)
Serum International Normalised Ratio (INR) • Used to measure the effect of anticoagulant
drugs such as warfarin
• Help diagnose a bleeding disorder; to help
estimate the severity of liver disease
Plasma Note – The RIQAS Point of Care range is constantly expanding to include new tests and analysers. Please contact us if your desired analyser or test is not currently displayed.Ordering Information
Panel Catalogue Number Lipids RQ9181/A Lipids + 1 panel RQ9181/B Lipids + 2 panels RQ9181/C Additional Sample RQ9181/D Glucose and Ketones RQ9188 INR RQ9189 Pipette Tips RQ9182 Bulbous pipette RQ9183 What Participants Say
Our unrivalled commitment to quality and service ensures high levels of customer satisfaction, this is evident from the responses to our latest customer satisfaction survey:
“All in all a quick and efficient service”
“Good online system”
“Very helpful team”
“Excellent training”
“They are an experienced team”
“Very satisfied with the service that we receive”
“Very good value for money”
“The website is great”Key Cycle Dates
RQ9181 Distribution Month Sample Distributed Result Submission Deadline January 2024 8th January 17th January February 2024 5th February 14th February March 2024 4th March 13th March April 2024 2nd April 10th April May 2024 6th May 15th May June 2024 3rd June 12th June July 2024 1st July 10th July August 2024 5th August 14th August September 2024 2nd September 11th September October 2024 7th October 16th October November 2024 4th November 13th November December 2024 2nd December 11th December Importance of Quality Assurance
Quality assurance is an essential aspect of any clinical/diagnostic testing service and is aimed at ensuring the accuracy and reliability of patients’ results. The right result allows the right clinical advice to be offered in a timely manner. Quality assurance operates at two levels:Internal Quality Control
Internal Quality Control includes operator training/ competency assessment, analyser/ test system maintenance, and adherence to policies/ processes. Whilst some point of care analysers include inbuilt quality checks, cross-check analysis against samples with known levels provides immediate assurance and evidence that a patient’s result is safe to report.External Quality Assessment
External Quality Assessment involves analysis of samples with unknown levels that have been distributed by an external organisation. Participants are informed how their results compare with other participants, hence providing independent evidence of performance. Increasingly, participation in an external quality assessment scheme is becoming a mandatory requirement where health and healthcare services are being provided.
EQA provides assurance to both staff and customers that testing provides accurate and reliable results.Want to know more?Visit our Importance of EQA page to learn more.
Want to know more?
Contact us or download the RIQAS Point of Care catalogue to learn more.
Continue Reading
Frequently Asked Questions
RIQAS
Contact Us
RIQAS Point of Care – FAQs
RIQAS Point of Care
RIQAS
Contact Us
ISO 22870- Are you meeting expectations?
Quality control has recently become crucial in the Point-of-Care (POC) field due to the introduction of ISO 22870 regulations and increased focus in patient safety. Quality control is critical in reducing turnaround time and saving money.
There is now an international standard specifically for POC testing, ISO 22870. This standard is intended to be used in conjunction with the standard for medical laboratories, ISO 15189. This means that aspects relating to Point-of-Care such as training, competence and documentation should be carefully planned, implemented and governed by a quality management system and there is a requirement for QC and EQA to be performed, where available.
POCT is typically carried out by non-laboratory staff, therefore when selecting the appropriate IQC material for POCT there are a number of key characteristics you must consider;
- Format of the material – QC material employed should be liquid stable, requiring no preparation, reducing the likelihood of human error and increasing convenience.
- Value assignment – all values must be accurately assigned. Look out for suppliers who use a large number of independent labs to determine the target value.
- Third party controls – manufactured independently from any specific instrument or method third party controls are designed to deliver unbiased performance assessment.
- Storage – for convenience controls should be liquid stable, as these can be easily stored in a fridge at 2oC – 8oC and won’t need to be shipped on dry ice.
- Stability – a control with a good open vial stability will mean that it can be used for longer with less waste produced, meaning it is more convenient for the medical professional to use.
- Transportation– the liquid stable controls can be conveniently stored at 2oC – 8oC reducing the need to ship on dry ice
- Minimal training– easy to use with little training required, therefore suitable for use by non-laboratory personnel
In addition to IQC, External Quality Assessment (EQA) must also be employed to ensure a comprehensive review of test system performance. It is best to select a programme that offers frequent reporting with a large database of users. This will enable rapid error identification and ultimately accurate and reliable patient testing.
Our Acusera liquid ready-to-use controls include:
- Blood Gas Control– A liquid stable control provided in easy to open ampoules for added convenience and ease-of-use. Assayed, method specific target values are provided for the most common blood gas instruments.
- Liquid Cardiac Control– This is a highly convenient liquid stable cardiac control offering excellent consistency. Assayed, instrument specific target values are provided for 8 cardiac markers, enabling flexibility and consolidation.
- Liquid Urinalysis Control– Liquid control that is compatible for use with both manual and automated methods of dipstick analysis. Available in convenient 12ml vials or 25ml dropper bottles with assayed ranges provided for 13 parameters covering the chemical examination of urine specimens.
- Liquid HbA1c Control– This is another highly convenient liquid ready-to-use control. With an open vial stability of 30 days, keeping waste and costs to a minimum.
Complementary EQA programmes are also available to meet the needs of ISO 22870.
ISO 22870:2006 in the Point-of-Care Testing (POCT) Market
Point-of-Care Testing (POCT)
The Point-of-Care testing market, better known as POCT, is growing rapidly as the demand for faster patient testing increases. This point is fully backed up through the results of the recent BIVDA (British IN-Vitro Diagnostics Association) survey of 2016. This survey focuses primarily on Point-of-Care Testing and there were a few questions asked that sparked an interest amongst us. The questions can be seen below;
“What are the challenges you face regarding POCT?”
“What do you see in the future for POCT?” (BIVDA, 2016)
Although many answers were put forward there was one (answer) that appeared for both questions. Accreditation. We found this intriguing yet far from surprising. POCT and accreditation go hand-in-hand, with laboratories striving to achieve ISO accreditation with the ultimate aim of allowing patients to have peace of mind that they are being tested properly and effectively.
ISO 22870:2006
The ISO standard that relates to POCT is ISO 22870:2006 Point of Care Testing- Requirements for quality and competence. This standard gives specific requirements applicable to POCT testing and apply when POCT is carried out in a hospital, clinic or a healthcare organisation providing ambulatory care. However, it is important to note and remember that ISO 22870 is not to be seen as a separate, standalone document, in fact, it is to be used in conjunction with ISO 15189:2012 (medical laboratories – particular requirements for quality & competence).
With accreditation in POCT becoming a major factor to laboratories, it is no surprise to see accreditation as one of the top answers to the two questions asked in the survey.
For laboratories looking to participate in point-of-care testing there are other factors of ISO 22870 that they must be aware of, one of the major factors is as follows;
“ISO 22870:2006 advises that where available, Internal Quality Control and participation in an External Quality Assessment (EQA) scheme is required in the point-of-care setting.”
How can Randox help?
Fortunately for laboratories, Randox are able to help out here. With a vast range of true third party controls and 32 comprehensive RIQAS (EQA) programmes, Randox can aid laboratories as they aim for ISO accreditation.
We have multiple products particularly suited to the POCT market including, Liquid Cardiac, Blood Gas and Urinalysis. These products are available both as internal quality controls and as EQA programmes.
Our Acusera range of true third party controls are conveniently supplied liquid ready-to-use, therefore requiring no preparation. This is a particular advantage in the POC environment were test results are required quickly and also were testing is not always performed by laboratory personnel. Supplied with assayed target values and manufactured from 100% human material, ensuring they act in the same manner as a patient sample, our Acusera controls are ideal for use at the point of care and will therefore aid a laboratory in gaining ISO accreditation.
Similarly, participation in our RIQAS EQA programme will also assist laboratories to meet regulatory requirements and achieve ISO accreditation. With over 40,000 laboratory participants in 123 countries, RIQAS is the largest international EQA scheme worldwide! Our Liquid Cardiac, Blood Gas and Urinalysis programmes are all supplied liquid ready-to-use, complementing their Acusera counterparts perfectly!
By using our Acusera controls and RIQAS EQA programmes side by side, a laboratory can confidently aim for ISO accreditation in the knowledge that they are meeting criteria.
Urinalysis External Quality Assessment
The RIQAS Urinalysis EQA programme is designed to monitor the performance of urine dipstick test using both manual and automated methods. All samples are supplied in a liquid ready-to-use format ideal for both clinical and point-of-care testing (POCT).
- Liquid ready-to-use
- 100% human urine
- Bi-monthly reporting
- Submit results and view reports online via RIQAS.Net
- Suitable for POCT
- Accredited to ISO/IEC 17043
- Cycle Starts – January 2025
Cat No | Kit Size | Frequency | Parameters | |
---|---|---|---|---|
RQ9138 | 6 x 12ml | Bi-monthly (1 x 12 month cycle) | 14 | |
Parameters
- Albumin
- Bilirubin
- Blood
- Creatinine
- Galactose
- Glucose
- hCG
- Ketones
- Leukocytes
- Nitrite
- pH
- Protein
- Specific Gravity
- Urobilinogen
Please note, product availability may vary country to country.
Related Products
Randox launches White Paper on Quality Control in POCT
Randox has launched the first in a series of White Papers, focusing on the importance of quality control in point-of-care testing (POCT). The White Paper is free to download and will help laboratories define an appropriate QC procedure for all POCT devices.
Patient testing at the point-of-care has increased dramatically in recent years, as technology makes it more convenient to test patient samples at the bedside producing rapid results and allowing immediate action. However, the benefits of this are only true if the results are both accurate and reliable, making quality control vitally important in the POC setting, just as it is in the laboratory.
A recent survey* identified that POCT is the largest source of error when compared to other sources of laboratory testing errors. Furthermore, the most common phase for errors in POCT is in the analytical stage, whereas in laboratory-based testing this is the least common source for errors. This highlights how vital it is to have a robust QC procedure in place for POCT as the potential risk of harm to a patient appears to be far greater for POC tests compared to those performed in a laboratory.
The White Paper from Randox covers the fundamentals of developing a POCT QC strategy in line with ISO15189 requirements, looking at who is responsible for QC, what QC is appropriate for different types of POC devices and tips for choosing IQC material and an EQA scheme.
The Paper can be downloaded from the Randox website here.
Randox second White Paper, which studies the importance of using 100% human serum controls to avoid lot-to-lot variations in immunoassay testing, will be available in December.