Take steps to prevent incorrect patient results by making one simple change
Take steps to prevent incorrect patient results by making one simple change
According to the NHS Litigation Authority; in 2015 within the UK alone, £193,680,744.30 was spent on ‘wrong diagnosis’ or ‘failed/delayed diagnosis’ causing huge financial strain and impact on labs.
With approximately 75% of clinical decisions and diagnosis based on laboratory test results. The only way to guarantee a high degree of accuracy is to implement a good Quality Control plan. The importance of this is recognised globally, several bodies exist internationally including ISO (International organisation for standardisation) who have developed a set of guidelines and quality systems to ensure the reliability of laboratory test results.
So what can you do to improve accuracy and reliability?
Choose a third party QC
ISO 151589:2012 Section 5.6.2.2 states that “the use of third party control materials should be considered, either instead of, or in addition to, any control materials supplied by the reagent or instrument manufacturer”.
First Party Controls are those manufactured by the instrument/reagent manufacturer. These controls are optimised specifically for use with the manufacturers test system and therefore will mask a multitude of weaknesses. First Party Controls tend to result in perceived accuracy and a biased assessment of performance.
Third Party Controls on the other hand are designed to be completely independent and are not optimised for use with a specific test or system. Leading manufacturers of third party controls will assign target values based on data collected from thousands of independent laboratories, ensuring the availability of statistically robust multi-method, multi-analyser data. Therefore laboratories using Third Party Controls can be assured of unbiased error detection across multiple platforms.
Randox Acusera is a world leading manufacturer of true third party controls providing a cost effective, high quality solution for any laboratory-regardless of size or budget.
Look out for QC samples with clinically relevant concentrations
ISO 15189:2012 states that ‘The laboratory should choose concentrations of control materials wherever possible, especially at or near clinical decision values, which ensure the validity of decisions made’.
It is important to assess the full clinical range of an assay i.e. the range between the lowest and highest results which can be reliably reported. In order to make sure a laboratory instrument is performing accurately across the full clinical range and in particular at the medical decision level, QC materials that cover low, normal and elevated concentrations should be used.
Due to the superior manufacturing process used by Randox, QC target values consistently cover the MDL of tests. By ensuring the controls in use cover clinical decision levels laboratories can be confident of the reliability and accuracy of the patient results they release.
Opt for a commutable control material
A good QC material has many essential properties but above all, controls must perform consistently and reflect the performance of patient samples – if a control meets these requirements then we can say it is commutable. Having a commutable control would aid in the prevention of incorrect patient results because they replicate the performance of a patient sample and react to the test system in a similar manner. Use of a commutable control will also reduce costly shifts in QC target values when reagent batch is changed.
At Randox we take quality seriously, that’s why all QC products are manufactured to the highest possible standard, delivering controls of unrivalled quality. Designed to be commutable, the Acusera range will ensure accurate and reliable instrument performance while simultaneously helping laboratories to meet ISO 15189:2012 requirements. A good QC process will include the use of Third Party Controls, Clinically Relevant Concentrations and controls which can be described as commutable. By employing Quality Control’s that encompass these traits, a laboratory professional can be certain that they have taken the necessary steps to decrease incorrect results and therefore potential misdiagnosis.
Liquid HbA1c Quality Control
Conveniently supplied liquid ready-to-use the Liquid HbA1c control is ideally suited to both clinical laboratories and POCT helping to significantly reduce preparation time. With a stability of 30 days waste and costs are also kept to a minimum.
Features & Benefits
- Liquid ready-to-use
- Human based whole blood
- Assayed target values
- Convenient bi-level pack covering clinically relevant decision levels
- Stable to expiry date at 2°C – 8°C
- Open vial stability of 30 days at 2°C – 8°C
Description Size Analytes Cat No
Liquid HbA1c Control 2 x 2 x 0.5 ml 1 HA10155
Liquid HbA1c Control Level 1 6 x 1 ml 1 HA10224
Liquid HbA1c Control Level 2 6 x 1 ml 1 HA10225
Analytes
HbA1c (Haemoglobin A1c)
Liquid CSF Quality Control
Providing a true third party solution for the measurement of Cerebrospinal Fluid (CSF), the Acusera Liquid CSF Control is designed to deliver an unbiased, independent assessment of analytical performance for 14 analytes, helping to ensure the results clinical laboratories release are accurate and reliable.
With an extended open vial stability of 30 days at 2oC – 8oC, the Acusera Liquid CSF Control will reduce waste, while remaining easy and convenient to use.
Features & Benefits
- Liquid ready-to-use samples requiring no preparation
- Human based material
- True third party control providing unbiased performance assessment
- Assayed target values available
- Shelf life of 2 years from the date of manufacture
- Open vial stability of 30 days for all analytes when stored at 2oC to 8oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Liquid CSF Control Level 1 | 10 x 3ml | 14 | CF10138 | |
Liquid CSF Control Level 2 | 10 x 3ml | 14 | CF10139 | |
Analytes
- Albumin
- Albumin (electrophoresis)*
- Alpha – 1- globulin (electrophoresis)*
- Alpha – 2- globulin (electrophoresis)*
- Beta- globulin (electrophoresis)*
- Chloride
- Gamma – globulin (electrophoresis)*
- Glucose
- hsIgA*
- hsIgG
- hsIgM*
- Lactate
- Protein (Total)
- Sodium
*No claims are made regarding values and stability.
PTH Quality Control
Providing a true third party solution for the measurement of Intact PTH, the new Acusera PTH Control will deliver an unbiased,
independent assessment of analytical performance with any instrument or method.
This notoriously unstable marker, present in a number of immunoassay controls, is now available in a liquid frozen format with an impressive 30 day open vial stability, reducing waste while remaining easy-to-use.
Features & Benefits
- Liquid Frozen
- 100% human serum
- Assayed target values available for many immunoassay platforms
- Stable to expiry date at -20°C to 70°C
- Open vial stability of 30 days at 2°C to 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
PTH Control Level 1 | 3 x 3 ml | 1 | PTH10110 | |
PTH Control Level 2 | 3 x 3 ml | 1 | PTH10111 | |
PTH Control Level 3 | 3 x 3 ml | 1 | PTH10112 | |
Analytes
- Intact PTH (Parathyroid Hormone)
Related Products
Evidence Immunoassay Control
Multi-analyte immunoassay control designed for use in the routine monitoring of the Randox Fertility, Thyroid and Tumour Marker Arrays.
Features & Benefits
- Lyophilised for enhanced stability
- Assayed values available for Randox Biochip systems
- 100% human serum
- Stable to expiry date at 2oC – 8oC
- Reconstituted stability of 7 days at 2oC – 8oC or 4 weeks at -20oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Evidence Immunoassay Control | 4 x 3 x 5ml | 14 | EV3570 | |
Analytes
- CEA
- Estradiol
- FSH
- Free T4
- Free T3
- Leutinising Hormone
- Prolactin
- Progesterone
- PSA (Total)
- PSA (Free)
- Testosterone
- Total T4
- Total T3
- TSH
Canine CRP Quality Control
A dedicated control designed for the use in the quality control of the Randox Canine CRP assay.
Features & Benefits
- Liquid ready-to-use
- Human CRP in a stabilised protein matrix
- Stable to expiry date at 2oC – 8oC
- Once open stable to expiry date at 2oC – 8oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Canine CRP Control Level 2 | 3 x 1ml | 1 | CP2803 | |
Canine CRP Control Level 3 | 3 x 1ml | 1 | CP2804 | |
Analytes
- Canine CRP
Microalbumin Calibrator
Dedicated Microalbumin calibrator designed for use with Microalbumin assays on a wide range of clinical analysers. 6 levels are provided in a liquid ready-to-use format making it both easy and convenient to use.
Features & Benefits
- Liquid ready-to-use
- 100% human serum
- Stable to expiry date at 2oC – 8oC
- Once opened stable to expiry date at 2oC – 8oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Microalbumin Calibrator Series | 6 x 2ml | 1 | MA1567 | |
Analytes
- Microalbumin
Lipid Control Calibrators
Apolipoprotein Calibrator
Multi-analyte, apolipoprotein calibrator with values provided for Apolipoprotein A-1 and Apolipoprotein B.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 7 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Apolipoprotein Calibrator | 3 x 1ml | 2 | LP3023 | |
Analytes
- Apo A-1
- Apo B
Apolipoprotein Calibrator 2
Multi-analyte calibrator covering four specialised apolipoprotein assays. A reconstituted stability of up to 28 days helps to keep waste and costs to a minimum.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 8 hours at 2°C – 8°C and one month at -20°C when frozen once
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Apolipoprotein Calibrator 2 | 3 x 1ml | 4 | LP5047 | |
Analytes
- Apolipoprotein A-II
- Apolipoprotein C-III
- Apolipoprotein C-II
- Apolipoprotein E
Lipoprotein (a) Calibrator
Dedicated Lipoprotein (a) calibrator specifically designed for use with the Randox Lipoprotein (a) assay.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 14 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Lipoprotein (a) Calibrator | 5 x 1ml | 1 | LP3404 | |
Analytes
- Lipoprotein (a)
Direct HDL/LDL Cholesterol Calibrator
Dedicated HDL and LDL cholesterol calibrator specifically designed for use with direct methods of measurement.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 5 days at 2°C – 8°C and 1 month at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
HDL/LDL Cholesterol Calibrator | 3 x 1ml | 2 | CH2673 | |
Analytes
- HDL Cholesterol
- LDL Cholesterol
sdLDL Cholesterol Calibrator
Dedicated sdLDL Cholesterol calibrator designed for use with the Randox sdLDL Cholesterol assay.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 5 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
sdLDL Cholesterol Calibrator | 3 x 1ml | 1 | CH5050 | |
Analytes
- sdLDL Cholesterol
Toxicology Control Calibrators
Analytes
- Oxazepam
Drugs of Abuse Array I Plus Calibrator
Multi-analyte calibrator designed for use with the Drugs of Abuse Array I Plus.
Features & Benefits
- Lyophilised for enhanced stability
- Stable to expiry date at 2oC – 8oC
- Urine- Reconstituted stability of 14 days at 2oC – 8oC
- Whole Blood – Reconstituted stability of 7 days at 2oC – 8oC or 14 days at -20oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Drugs of Abuse Assay I Plus (Urine) Calibrators | 9 x 1ml | 14 | EV3744 | |
Analytes
- Amphetamine
- Barbiturates
- Benzodiazepine 1
- Benzodiazepine 2
- Buprenorphine
- Cannabinoids
- Cocaine Metabolite
- MDMA
- Methadone
- Methamphetamine
- Opiates
- Phencyclidine
- Tricyclic Antidepressants
- Creatinine
Drugs of Abuse Array II Calibrators
Dedicated calibrator designed for use the Drugs of Abuse Array II control.
Features & Benefits
- Lyophilised for enhanced stability
- Stable to expiry at 2oC – 8oC
- Urine- Reconstituted stability of 7 days at 2oC – 8oC or 28 days at -20oC
- Whole Blood – Reconstituted stability of 7 days at 2oC – 8oC or 28 days at -20oC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Drugs of Abuse Array II (Whole Blood) Calibrator Series | 9 x 1ml | 11 | EV3687 | |
Analytes
- 3,4 Methylenedioxymethamphetamine (MDMA)
- Ketamine
- Lysergic Acid Diethylamide (LSD)
- Methaqualone
- Buprenorphine
- Fentanyl
- Generic Opioids
- Oxycodone I
- Oxycodone II
- Propoxyphene
- Creatinine
Drugs of Abuse Array III Calibrators
Multi-analyte calibrator designed for use with the Drugs of Abuse Array III control.
Features & Benefits
- Lyophilised for enhanced stability/li>
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 7 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Drugs of Abuse Array III (Urine) Calibrator Series | 9 x 1ml | 11 | EV3829 | |
Drugs of Abuse Array III (Whole Blood) Calibrator Series | 9 x 1ml | 11 | EV3797 | |
Analytes
- Chloral Hydrate Metabolite
- Ethyl Glucuronide
- Fentanyl
- Ketamine Metabolite
- Meperidine
- Meprobamate
- Zaleplon
- Zolpidem
- Zopiclone
- 7-amino Flunitrazepam
- Creatinine
Drugs of Abuse Array IV Calibrator
Multi-analyte calibrator designed for use with the Drugs of Abuse Array IV control.
Features & Benefits
- Lyophilised for enhanced stability
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 7 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Drugs of Abuse Array IV (Whole Blood) Calibrator | 9 x 1ml | 14 | EV3808 | |
Analytes
- Acetaminophen
- Dextromethorphan
- Escitalopram
- Fluoxetine
- Haloperidol
- Ibuprofen
- Methylphenidate
- Salicylate
- Salicyluric Acid
- Sertraline
- Tramadol
- Trazodone
- Tricyclic Antidepressants
- Creatinine
Drugs of Abuse Array V Calibrators
Multi-analyte calibrator designed for use with the Drugs of Abuse Array V control.
Features & Benefits
- Lyophilised for enhanced stability
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 7 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Drugs of Abuse Array V (Urine) Calibrator Series | 9 x 1ml | 10 | EV3815 | |
Drugs of Abuse Array V (Whole Blood) Calibrator Series | 9 x 1ml | 10 | EV3847 | |
Analytes
- Bath Salts 1 (Methcathinone and Mephedrone)
- Bath Salts 2 (MDPV)
- Benzylpiperazines
- Mescaline
- Phenylpiperazines
- Salvinorin
- Synthetic Cannabinoids 1
- Synthetic Cannabinoids 2
- Synthetic Cannabinoids 3
- Synthetic Cannabinoids 4
Therapeutic Drugs Control Calibrator
Therapeutic Drug Calibrator
Multi-analyte calibrator set covering 5 different therapeutic drugs. Six levels are available with a reconstituted stability of 4 weeks helping to keep waste to a minimum.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 4 weeks at 2°C – 8°C or 8 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Therapeutic Drug Calibrator Series | 6 x 3ml | 5 | TD3417 | |
Analytes
- Carbamazepine
- Digoxin
- Phenobarbital
- Phenytoin
- Valproic Acid