Monitoring response to exercise is vitally important to an athlete and trainer. While a heavy training schedule can lead to chronic immunosuppression in athletes, it is essential that they receive the appropriate care in the case of a dip in health state. Eliminating the risk of inflammation and infection is essential to preventing disruptions to practice and performance.
VeraSTAT Test Menu
The VeraSTAT testing menu is designed to monitor an athletes immune response to exercise. C-Reactive Protein (CRP) levels are used to guide the treatment of bacterial infections or inflammation associated with tissue injury and other inflammatory disorders. On the other hand, Mxyovirus Resistance Protein 1 (MxA) is used as a key indicator of viral infections. These tests used in combination, can allow healthcare clinicians to determine the best course of treatment and get the athlete back to full health
C-Reactive Protein (CRP)
CRP is a Key indicator of inflammation and stress, often resulting from the breakdown in tissues. Overtraining can lead to elevated levels of CRP in the body.
Myxovirus Resistance Protein I (MxA)
MxA is a key indicator of a viral infection which may impact physical performance and activity levels. Unexplained failures are often attributed to recent or current infections.
Identification and Differentiation of Viral and Bacterial Respiratory Infection to Guide Antibiotic Stewardship
Identification and Differentiation of Viral and Bacterial Respiratory Infection to Guide Antibiotic Stewardship
The development of point-of-care testing is critical in the identification and differentiation between bacterial and viral respiratory infections. Defining the indications of infection to improve antibiotic stewardship, ensures that patients are protected from unnecessary antibiotic use and antibiotic resistance. It has been shown that particular protein biomarkers, such as myxovirus resistance protein (MxA) and C-reactive protein (CRP), differentiate infections between bacterial and viral. Using point-of-care platforms, such as Randox’s VeraSTAT, for detection of these protein biomarkers may provide more rapid and cost-effective discriminating tools.
The treatment of bacterial and viral infections can differ significantly, however people are often treated with empirical antibiotics due to a lack of paid and accurate testing. Although early intervention of infection is urgent, current diagnostic methods are either time intensive or inaccurate. The challenges clinicians are faced with in the differentiation of viral or bacterial respiratory infection can lead to delayed diagnosis, misappropriation of antibiotics and increased healthcare costs.
MxA protein has the potential to greatly enhance the rapid detection of viral respiratory infections as it increases significantly when there is actuate viral infection. CRP is the dominant acute phase protein often used to guide treatment of a bacterial infection or inflammation associated with tissue injury, inflammatory disorders, and associated diseases.
CRP & MxA together, allow clinicians to make appropriate decisions in supporting antimicrobial stewardship and guide the appropriate use of antibiotics, saving time performing unnecessary tests, providing unnecessary treatment which missing the opportunity to provide the right treatment in a timely manner.
The Randox VeraSTAT is a simple, accurate, portable point of care device which delivers rapid results via the use of patented cathodic electrochemiluminescence technology (C-ECL). Designed with the aim of offering users the next generation of rapid diagnosis, the VeraSTAT eliminates the requirement to send samples to a laboratory and instead returns results in as little as 6 minutes.
- Eliminates delays in sending samples to the lab and facilitate immediate decision making at the point of care.
- Lightweight, portable and convenient, the Randox VeraSTAT can be used in a variety of locations to deliver results as required, such as a GP surgery or Emergency Department.
- Intuitive user interface guides the operator through the entire testing process.
- All necessary reagents are conveniently included in each single use, sealed cassette with no preparation required. All necessary consumables are supplied with the kit.
- The Randox VeraSTAT allows for results to be exported via Bluetooth connectivity.
- Flexible test menu comprising of a range of immunoassay, protein, inflammatory, diabetes & infectious disease markers.
Novel testing approaches identifying the type of infection at the point of care are essential in accurately guiding appropriate antibiotic treatment. Although these tests can’t determine what type of viral or bacterial infection a patient has, it will determine whether the infection is viral or bacterial, further testing is then carried out to determine what type of pathogen the patient has via PCR – the gold standard. The ability to distinguish between viral and bacterial infections is the most effective guide for clinical decision making and is an innovative tool for antibiotic stewardship.
References
1 – Fleming-Dutra K.E., Hersh A.L., Shapiro D.J. Prevalence of inappropriate antibiotic prescriptions among US ambulatory care visits, 2010–2011. JAMA. 2016;315:1864–1873. doi: 10.1001/jama.2016.4151.
2 – Cals JW, Hopstaken RM, Butler CC, Hood K, Severens JL, Dinant GJ. Improving management of patients with acute cough by C-reactive protein point of care testing and communication training (IMPAC3T): study protocol of a cluster randomised controlled trial. BMC Fam Pract. 2007;8:15.
3- New report calls for urgent action to avert antimicrobial resistance crisis [Internet]. World Health Organization. World Health Organization; 2019
4 – Hutchings MI, Truman AW, Wilkinson B. Antibiotics: past, present and future. Curr Opin Microbiol. (2019) 51:72–80. doi: 10.1016/j.mib.2019.10.008
For more enquiries please contact the Marketing team: market@randox.com
ABOUT RANDOX
NEWS
VACANCIES
OUR PEOPLE
CRP & MxA VeraSTAT
VeraSTAT | CRP & MxA
Rapid Differentiation of Viral & Bacterial Respiratory Infections
MxA protein has the potential to greatly enhance the rapid detection of viral respiratory infections and increases significantly when there is actuate viral infection.
CRP is the dominant acute phase protein often used to guide treatment of a bacterial infection or inflammation associated with tissue injury, inflammatory disorders, and associated diseases.
Together, allow clinicians to make appropriate decision in supporting antimicrobial stewardship and guide thappropriate use of antibiotics.
MxA
VeraSTAT MxA kit is an in vitro near-patient diagnostic test for the quantitative determination of Myxovirus resistance protein A (MxA) from whole blood. The MxA Kit is used for detection of acute respiratory tract viral infections from symptomatic patients.
CRP
VeraSTAT CRP kit is an in vitro near-patient diagnostic test for the quantitative determination of C-reactive protein (CRP) from whole blood to assess the inflammatory status of the body.
Sample Volume- 7 μL
Sample Type- Whole Blood
Measuring Time- 11 minutes
Ordering Information: VS1004
Sample Volume- 5 μL
Sample Type- Whole Blood
Measuring Time- 6 minutes
Ordering Information: VS1003
Useful Resources
VERASTAT-V
GET IN TOUCH
VERASTAT BROCHURE
VeraSTAT
VeraSTAT | Excellence at the Point of Care
Accurate & Reliable Results in Minutes
Why Choose the VeraSTAT?
The Randox VeraSTAT is a simple, accurate, portable point of care device which delivers rapid results via the use of patented cathodic electrochemiluminescence technology (C-ECL).
Through this technology, the target analyte in the patient sample reacts with the labelled antibody and captured antibody. After the reaction, unbound or excess labelled antibody is washed away and the labelled antibody complex is excited with electricity, with the electrochemiuminescence being measured and an accurate result produced.
Designed with the aim of offering users the next generation of rapid diagnosis, the VeraSTAT eliminates the requirement to send samples to a laboratory and instead returns results in as little as 6 minutes when and where required.
The superiority of the VeraSTAT allows for users to overcome performance limitations of previous generation tests relating to sensitivity, accuracy, ease of use and cost efficiency. This, combined with a versatile test menu, means that the Randox VeraSTAT is built to outshine and enhance detection in any setting.
Click here to download Windows App:
- Download VeraSTAT Analyzer windows application to your computer.
- Extract the zipped file and double click VeraSTATsetup
- Follow the application install instruction to install the application on device
VeraSTAT User Guide
VeraSTAT Test Menu
C-Reactive Protein (CRP)
CRP is the dominant acute phase protein often used to guide treatment of a bacterial infection or inflammation associated with tissue injury, inflammatory disorders and associated diseases.
Myxovirus Resistance Protein I (MxA)
An informative general marker for the most common acute viral infections. MxA protein has the potential to greatly enhance the rapid distinction between viral and bacterial respiratory infections.