Haematology Quality Control
Combining 45 analytes in total the Randox Acusera Haematology quality control completely covers the commonly tested full blood profile in a single control. Providing a true third party solution for Sysmex and Mindray haematology analysers with 5-part differential technology an unbiased, independent assessment of analytical performance is guaranteed.
Features & Benefits
- Liquid ready-to-use
- 100% Human whole blood
- Barcoded labels enabling quick and easy sample recognition
- Stable for 70 days at 2ºC to 8°C
- Open vial stability of 14 days at 2ºC to 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Haematology Tri-Level | 3 x 2 x 4.5 ml | 45 | HM5162 | |
Analytes
- Basophils (BASO)*
- % Basophils (% BASO)
- BASO-X
- BASO –Y
- DIFF-X
- DIFF-Y
- Eosinophils (EOS)
- % Eosinophils (%EOS)
- FSC-X
- Haematocrit (HCT)
- Haemoglobin (HGB)
- Haemopioetic Progenitor Cell (HPC)
- IMIDC
- IMIRF
- Immature Granulocytes (IG)
- % Immature Granulocytes (%IG)
- Immature Myeloid Information (IMI)
- Immature Platelet Fraction (IPF)
- Lymphocytes (LYMPH)
- % Lymphocytes (% LYMPH)
- Mean Corpuscular Volume (MCV)
- Mean Corpuscular Haemoglobin (MCH)
- Mean Corpuscular Haemoglobin Concentration (MCHC)
- Mean Platelet Volume (MPV)
- Monocytes (MONO)
- % Monocytes (% MONO)
- Neutrophils (NEUT)
- % Neutrophils (% NEUT)
- Nucleated Red Blood Cells X (NRBC-X)
- Nucleated Red Blood Cells Y (NRBC-Y)
- Nucleated Red Blood Cells (NRBC)*
- % Nucleated Red Blood Cells (%NRBC)
- Platelet Distribution Width (PDW)
- Platelet Large Cell Ratio (P-LCR)
- Plateletcrit (PCT)
- Platelets (PLT)
- Platelets Optical Count (PLT-0)
-
Red Blood Cells (RBC)
- Red Blood Cell X (RBC-X)
- Red Blood Cell Y (RBC-Y)
- Red Blood Cell Distribution Width CV (RDW-CV)
- Red Blood Cell Distribution Width SD (RDW-SD)
- Red Blood Cells Optical Count (RBC-O)
- White Blood Cells (WBC)
- White Blood Cells Differential (WBC-D)
*This product may not be suitable for the control of NRBC# and Basophils on some Sysmex models
Coagulation Quality Control
The Randox Acusera Coagulation Quality Control covers 16 analytes in total including a wide variety of factor assays, basic coagulation and thrombophilia parameters. As an assayed control instrument and method specific target values and ranges are provided.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human plasma
- Assayed target values provided for 16 analytes
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 24 hours at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Coagulation Control Level 1 | 12 x 1ml | 16 | CG5021 | |
Coagulation Control level 2 | 12 x 1ml | 16 | CG5022 | |
Coagulation Control Level 3 | 12 x 1ml | 16 | CG5023 | |
Analytes
- Prothrombin Time
- Activated Partial Thromboplastin Time
- Thrombin Time
- Fibrinogen
- Antithrombin III
- Factor II
- Factor V
- Factor VII
- Factor VIII
- Factor IX
- Factor X
- Factor XI
- Factor XII
- Plasminogen
- Protein C
- Protein S