Lipid Quality Controls
Lipid Quality Controls
Our Acusera Lipid Quality Controls have been manufactured from 100% human serum to ensure they are commutable, mirroring the behaviour of a real patient sample, with minimal lot to lot value shifts. As all of our lipid quality controls are lyophilised, they contain no stabilisers or preservatives which are known to affect the overall performance of the controls. The multi-analyte controls enable test menu consolidation which, along with the four year shelf life from the date of manufacture, ensures minimal waste helping your lab reduce costs.
Lyophilised Lipid Quality Controls
Haematology Quality Control
Combining 45 analytes in total the Randox Acusera Haematology quality control completely covers the commonly tested full blood profile in a single control. Providing a true third party solution for Sysmex and Mindray haematology analysers with 5-part differential technology an unbiased, independent assessment of analytical performance is guaranteed.
Features & Benefits
- Liquid ready-to-use
- 100% Human whole blood
- Barcoded labels enabling quick and easy sample recognition
- Stable for 70 days at 2ºC to 8°C
- Open vial stability of 14 days at 2ºC to 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Haematology Tri-Level | 3 x 2 x 4.5 ml | 45 | HM5162 | |
Analytes
- Basophils (BASO)*
- % Basophils (% BASO)
- BASO-X
- BASO –Y
- DIFF-X
- DIFF-Y
- Eosinophils (EOS)
- % Eosinophils (%EOS)
- FSC-X
- Haematocrit (HCT)
- Haemoglobin (HGB)
- Haemopioetic Progenitor Cell (HPC)
- IMIDC
- IMIRF
- Immature Granulocytes (IG)
- % Immature Granulocytes (%IG)
- Immature Myeloid Information (IMI)
- Immature Platelet Fraction (IPF)
- Lymphocytes (LYMPH)
- % Lymphocytes (% LYMPH)
- Mean Corpuscular Volume (MCV)
- Mean Corpuscular Haemoglobin (MCH)
- Mean Corpuscular Haemoglobin Concentration (MCHC)
- Mean Platelet Volume (MPV)
- Monocytes (MONO)
- % Monocytes (% MONO)
- Neutrophils (NEUT)
- % Neutrophils (% NEUT)
- Nucleated Red Blood Cells X (NRBC-X)
- Nucleated Red Blood Cells Y (NRBC-Y)
- Nucleated Red Blood Cells (NRBC)*
- % Nucleated Red Blood Cells (%NRBC)
- Platelet Distribution Width (PDW)
- Platelet Large Cell Ratio (P-LCR)
- Plateletcrit (PCT)
- Platelets (PLT)
- Platelets Optical Count (PLT-0)
-
Red Blood Cells (RBC)
- Red Blood Cell X (RBC-X)
- Red Blood Cell Y (RBC-Y)
- Red Blood Cell Distribution Width CV (RDW-CV)
- Red Blood Cell Distribution Width SD (RDW-SD)
- Red Blood Cells Optical Count (RBC-O)
- White Blood Cells (WBC)
- White Blood Cells Differential (WBC-D)
*This product may not be suitable for the control of NRBC# and Basophils on some Sysmex models
Coagulation Quality Control
The Randox Acusera Coagulation Quality Control covers 16 analytes in total including a wide variety of factor assays, basic coagulation and thrombophilia parameters. As an assayed control instrument and method specific target values and ranges are provided.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human plasma
- Assayed target values provided for 16 analytes
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 24 hours at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Coagulation Control Level 1 | 12 x 1ml | 16 | CG5021 | |
Coagulation Control level 2 | 12 x 1ml | 16 | CG5022 | |
Coagulation Control Level 3 | 12 x 1ml | 16 | CG5023 | |
Analytes
- Prothrombin Time
- Activated Partial Thromboplastin Time
- Thrombin Time
- Fibrinogen
- Antithrombin III
- Factor II
- Factor V
- Factor VII
- Factor VIII
- Factor IX
- Factor X
- Factor XI
- Factor XII
- Plasminogen
- Protein C
- Protein S