HbA1c Quality Control
HbA1c Quality Control
The Randox Acusera HbA1c control is designed for use in the quality control of both HbA1c and Total Haemoglobin assays. Assayed instrument and method specific target values and ranges are provided for all major systems and methods including HPLC. A reconstituted stability of 4 weeks keeps waste to a minimum and helps to reduce costs.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human whole blood
- Assayed target values provided for 2 parameters
- Convenient bi-level pack containing two clinically significant levels of control
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 4 weeks at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
HbA1c Control | 2 x 2 x 0.5 ml | 2 | HA5072 | |
Analytes
- HbA1c
- Total Haemoglobin
Glycerol Quality Control
The Randox Acusera Glycerol control is designed to monitor the accuracy and precision of glycerol assay on a wide range of clinical chemistry analysers.
Features & Benefits
- Lyophilised for enhanced stability
- Human based serum
- Assayed target values provided
- Stable to expiry at 2°C – 8°C
- Reconstituted stability of 7 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Glycerol Control | 3 x 5ml | 1 | GY1369 | |
Analytes
- Glycerol
Bilirubin Elevated Quality Control
The Randox Acusera Bilirubin Elevated control is designed to monitor the accuracy and precision of bilirubin assays used in paediatric testing. Assayed method specific target values are provided for both Total and Direct Bilirubin.
Features & Benefits
- Lyophilised for enhanced stability
- Bovine based serum
- Assayed target values provided for Total and Direct Bilirubin
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 5 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Bilirubin Elevated Control | 10 x 3ml | 2 | BE454 | |
Analytes
- Direct Bilirubin
- Total Bilirubin
Bovine Chemistry Assayed Quality Control
The Randox Acusera Bovine Chemistry Assayed control is designed for use in the routine monitoring of accuracy and precision. Assayed method and instrument specific target values are provided for 45 analytes including commonly used veterinary tests such as NEFA, Bile Acids, Lactate and D-3 Hydroxybutyrate.
Features & Benefits
- Lyophilised for enhanced stability
- Bovine based serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 7 days at 2°C – 8°C or 4 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Bovine Chemistry Assayed Level 1 | 20 x 5ml | 45 | AL1027 | |
Bovine Chemistry Assayed Level 2 | 20 x 5ml | 45 | AN1026 | |
Bovine Chemistry Assayed Level 3 | 20 x 5ml | 45 | AE1032 | |
Analytes
- Acid Phosphatase (Prostatic)
- Acid Phosphatase (Total)
- Albumin
- Alkaline Phosphatase (ALP) /li>
- ALT (GPT)
- Amylase
- AST (GOT)
- Bicarbonate
- Bile Acids
- Bilirubin (Direct)
- Bilirubin (Total)
- Calcium
- Chloride
- Cholesterol
- CK (Total)
- Copper
- Cortisol
- Creatinine
- D-3-Hydroxybutyrate
- GLDH
- Glucose
- Iron
- Iron (TIBC)
- Lactate
- Lactate Dehydrogenase (LDH)
- Lipase
- Lithium
- Magnesium
- NEFA
- Osmolality
- Phosphate (Inorganic)
- Potassium
- Protein (Total)
- PSA (Total)
- Sodium
- T3 (Total)
- T4 (Free)
- T4 (Total)
- Triglycerides
- Urea
- Uric Acid (Urate)
- Vitamin B12
- Zinc
- α-HBDH
- γGT
Precision Chemistry Premium Plus Quality Control
The Randox Acusera Precision Chemistry Premium Plus control is designed to monitor the precision of routine chemistry tests. As a multi-analyte control it covers 74 analytes including a wide range of cardiac markers, drugs, immunoassays, lipids and proteins.
Features & Benefits
- Lyophilised for enhanced stability
- Human based serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 7 days at 2°C – 8°C or 4 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Precision Chemistry Premium Plus Level 2 | 20 x 5ml | 83 | UN1557 | |
Precision Chemistry Premium Plus Level 3 | 20 x 5ml | 83 | UE1558 | |
Analytes
- CK (Total)
- Digoxin
- Gentamicin
- Lithium
- Paracetamol
- Salicylate
- Theophylline
- Tobramycin
- α-Fetoprotein (AFP)
- CEA
- Cortisol
- Folate
- Prolactin
- PSA (Total)
- T3 (Free)
- T3 (Total)
- T4 (Free)
- T4 (Total)
- Vitamin B12
- Apolipoprotein A-I
- Apolipoprotein B
- Cholesterol (HDL)
- Cholesterol (Total)
- NEFA
- Triglycerides
- a-1-Acid Glycoprotein
- a-1-Antitrypsin
- Ceruloplasmin
- Complement C3
- Complement C4
- CRP
- Ferritin
- Haptoglobin
- Immunoglobulin A (IgA)
- Immunoglobulin E (IgE)
- Immunoglobulin G (IgG)
- Immunoglobulin M (IgM)
- Prealbumin
- Protein (Total)
- Transferrin
- a-HBDH
- Acid Phosphatase (Total)
- Albumin
- Alkaline Phosphatase (ALP)
- ALT (GPT)
- Amylase
- Amylase (Pancreatic)
- AST (GOT)
- Bicarbonate
- Bile Acids
- Bilirubin (Direct)
- Bilirubin (Total)
- Calcium
- Chloride
- Cholinesterase
- Creatinine
- D-3-Hydroxybutyrate
- gGT
- GLDH
- Glucose
- Iron
- Iron (TIBC)
- Lactate
- Lactate Dehydrogenase (LDH)
- Lipase
- Magnesium
- Osmolality
- Phosphate (Inorganic)
- Potassium
- Sodium
- Urea
- Uric Acid (Urate)
- Copper
- Zinc
Assayed Chemistry Premium Plus Quality Control
The Randox Acusera Assayed Chemistry Premium Plus Control is designed to monitor both accuracy and precision of routine chemistry assays. As a true third party control assayed instrument and method specific target values are provided for 66 analytes including a wide range of lipids, cardiac markers, therapeutic drugs, immunoassays, proteins, routine chemistries and trace metals. Electrophoresis targets are also provided as a percentage breakdown of total protein.
Features & Benefits
- Lyophilised for enhanced stability
- Human based serum
- Typical Osmolality values: Level 2 is 300 mOsm/kg, Level 3 is 370 mOsm/kg
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of up to 7 days at 2°C – 8°C or 4 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Assayed Chemistry Premium Plus Level 2 | 20 x 5ml | 66 | HN1530 | |
Assayed Chemistry Premium Plus Level 3 | 20 x 5ml | 66 | HE1532 | |
Assayed Chemistry Premium Plus Level 2 and 3 | 2 x 5 x 5ml | 66 | HS2611 | |
Analytes
- Alpha-1-Globulin (Electrophoresis)
- Alpha-2-Globulin (Electrophoresis)
- Alpha-HBDH
- Acid Phosphatase (Total)
- Albumin
- Albumin (Electrophoresis)
- Alkaline Phosphatase
- ALT
- Amylase Pancreatic
- Amylase Total
- Apolipoprotein A-1
- Apolipoprotein B
- AST
- Beta-1-Globulin (Electrophoresis)
- Bicarbonate
- Bile Acids
- Bilirubin Direct
- Bilirubin Total
- Calcium
- Chloride
- Cholesterol
- Cholinesterase
- CK Total
- Copper
- Cortisol
- Creatinine
- D-3-Hydroxybutyrate
- Digoxin
- Folate
- Free T4
- Gamma-Globulin (Electrophoresis)
- Gentamicin
- Gamma-GT
- GLDH
- Glucose
- HDL Cholesterol
- Immunoglobulin A
- Immunoglobulin G
- Immunoglobulin M
- Iron
- Iron (TIBC)
- Lactate
- LDH
- Lipase
- Lithium
- Magnesium
- NEFA
- Osmolality
- Paracetamol
- Phosphate Inorganic
- Potassium
- Protein Total
- PSA Total
- Salicylate
- Sodium
- Theophylline
- Thyroid Stimulating Hormone
- Tobramycin
- Total T3
- Total T4
- Transferrin
- Triglycerides
- Urea
- Uric Acid
- Vitamin B12
- Zinc
CK-MB Quality Control
The Randox Acusera dedicated CK-MB control is designed for use in the routine monitoring of both accuracy and precision. Accurately assigned target values and ranges are provided for both serum start, substrate start and CK-NAC methods.
Features & Benefits
- Lyophilised for enhanced stability
- 100% human serum
- Assayed target values provided for 2 cardiac markers
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 5 days at 2ºC to 8ºC, , 8 hours at +25ºC and 28 days at -20ºC
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
CK-MB Control | 10 x 2ml | 2 | CK1212 | |
Cardiac Quality Control
The Randox Acusera Tri-Level Cardiac Quality Control is designed for use in the routine monitoring of both accuracy and precision. Assayed instrument and method specific target values are provided for 7 cardiac markers along with temperature specific target values for CK and CK-MB.
Features & Benefits
- Lyophilised for enhanced stability
- Human based serum
- Assayed target values provided for 7 cardiac markers
- Cut off levels for Troponin I and T in line with internationally recommended levels
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 5 days at 2°C – 8°C or 4 weeks at -20°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Tri-Level Cardiac Control | 3 x 1ml | 7 | CQ3100 | |
Tri-Level Cardiac Control | 3 x 2ml | 7 | CQ3259 | |
Analytes
- CK Total
- CK-MB (Mass)
- Myoglobin
- Troponin T
- CK-MB (Activity)
- Homocysteine
- Troponin I
Related Products
Total Antioxidant Status Quality Control
Dedicated control for use in the routine monitoring of the Randox Total Antioxidant Status assay on clinical chemistry analysers
Features & Benefits
- Lyophilised for enhanced stability
- Bovine based serum
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 2 days at 2°C – 8°C or 12 hours at 15°C – 25°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Total Antioxidant Status Control | 10 x 5 ml | 1 | NX2331 | |
Analytes
- Total Antioxidant Status
Related Products
Superoxide Dismutase (Ransod) Quality Control
A dedicated Superoxide Dismutase control for use in the routine monitoring of the Randox Ransod assay on clinical chemistry analysers.
Features & Benefits
- Lyophilised for enhanced stability
- Bovine based whole blood
- Stable to expiry date at 2°C – 8°C
- Reconstituted stability of 10 days at 2°C – 8°C
Description | Size | Analytes | Cat No | |
---|---|---|---|---|
Ransod (superoxide dismutase) | 10 x 1 ml | 1 | SD126 | |
Analytes
- Superoxide Dismutase