Protected: RX series (Concept)
Product Spotlight: Liquid Assayed Chemistry Premium Plus
Routine clinical chemistry is the basis of a laboratory’s daily testing, it is, therefore, important to choose a chemistry control which offers the greatest consolidation, accuracy, and stability.
The Acusera Liquid Assayed Chemistry Premium Plus control is one of the most comprehensive chemistry controls on the market, with instrument specific values provided for 99 analytes. A unique combination of proteins, lipids, cardiac markers, therapeutic drugs, immunoassay, and routine chemistry parameters enables effective consolidation, as well as time and cost savings. As a true third party control, it is manufactured independently from any analyser, with values assigned using our unique value assignment process, target values are available for several common analyser platforms. Containing an impressive array of lipids and Immunoassay parameters, this Acusera Chemistry control offers unrivaled consolidation.
Key Features & Benefits
- Liquid for ease of use
- Human based serum
- Assayed instrument specific target values and ranges
- High levels of CRP and other proteins eliminate the need for multiple controls
- Stable to expiry when stored at -20°C to -70°C
- Open vial stability of up to 7 days at 2°C – 8°C
Analytes (click to expand)
Albumin (Electrophoresis)
Alpha-1-Globulin (Electrophoresis)
Alpha-2-Globulin (Electrophoresis)
Beta-Globulin (Electrophoresis)
Gamma-Globulin (Electrophoresis)
Alpha-HBDH
α-1- Acid Glycoprotein
α-1-Antitrypsin
Β-2-Microglobulin
Acid Phosphatase (Total)
AFP
Albumin
Alkaline Phosphatase
Amikacin
ALT
Amylase
Amylase (Pancreatic)
Apo A-1
Apo B
AST
Bicarbonate
Bile Acids
Bilirubin Direct
Bilirubin Total
C-Reactive Protein
Caffeine
Calcium
Carbamazepine
CEA
Ceruloplasmin
Chloride
Cholesterol
CholinesteraseCK Total
Complement C3
Complement C4
Copper
Cortisol
Creatinine
D-3-Hydroxybutyrate
DHEA Sulphate
Digoxin
Ethanol
Ferritin
Folate
FSH
Free T3
Free T4
Gamma GT
Gentamicin
GLDH
Glucose
Haptoglobin
hCG
HDL Cholesterol
IgA
IgE
IgG
IgM
Iron
Lactate
LAP
LDH
LDL Cholesterol
Leutinising Hormone
LipaseLP(a)
Lithium
Magnesium
Myoglobin
Osmolality
Paracetamol
Phenobarbital
Phenytoin
Phosphate Inorganic
Potassium
Prealbumin
Progesterone
Prolactin
Protein Total
PSA Total
Salicylate
Sodium
Testosterone
Theophylline
Total T3
Total T4
TSH
TIBC
Transferrin
Triglycerides
Troponin T
T Uptake
Urea
Uric Acid
Valproic Acid
Vancomycin
Vitamin B12
Zinc
C-Reactive Protein (CRP)
CRP is a protein made by the liver and released into the blood within a few hours after tissue injury, the start of an infection, or other cause of inflammation. It is tested to detect the presence of inflammation and can be used to monitor the response to treatment for inflammatory disorders. CRP is included in the Liquid Assayed Chemistry Premium Plus control, ensuring accurate instrument performance at key decision levels and further reduces the number of individual controls required. CRP is available at elevated levels in the level three control.
Troponin T (TnT)
A troponin test measures the levels of troponin proteins in blood and is used when a patient is suspected to have suffered a heart attack. These proteins are released when the heart muscle has been damaged, such as with a heart attack. More damage to the heart would result in a higher level of Troponin T. As a highly consolidated contorol, the Liquid Assayed Chemistry Premium Plus includes Troponin T, meaning a separate control is not required.
Metabolism: how Randox is helping to diagnose metabolic conditions
Many people talk about their metabolism as if it is a muscle or organ they can somehow control. In reality, your metabolism refers to a series of chemical processes in each cell that turn the calories you eat into fuel to keep you alive.
Metabolism is the biochemical process of combining nutrients with oxygen to release the energy our bodies need to function. Your resting metabolic rate (RMR) is the number of calories your body burns to maintain vital body functions such as heart rate, brain function and breathing. RMR accounts for up to 75 percent of the calories you burn each day. Knowledge of your individual RMR is a critical piece of information to appropriately establish daily calorie needs.
The body’s major organs — the brain, liver, kidneys, and heart — account for about half of the energy burned at rest, while fat, the digestive system, and especially the body’s muscles account for the rest.
Did you know?
Approximately 20-25% of the world’s adult population have metabolic syndrome?
A common misconception surrounding metabolic health is that it refers solely to your weight, and if you are overweight you are considered to be unhealthy. But in actual fact this may not be entirely true. Good metabolism means that your body is in good overall health, which doesn’t account for just your weight! Common metabolic disorders include genetic metabolic disorders, diabetes and metabolic syndrome. Understanding and testing to see how well your metabolism is functioning is key to ensuring long lasting health.
Genetics
There are a number of genetic metabolic disorders caused by mutations of single genes. Examples of common disordersinclude Gaucher’s disease, hemochromatosis and cystic fibrosis. Gaucher’s disease is a genetic disorder that affects the body’s ability to break down fat that can accumulate in the liver/spleen and bone marrow. Hemochromatosis is a condition that is caused by the over-absorption and build-up of iron while cystic fibrosis is a metabolic disorder that appears as a result of a build-up of mucus in lungs/liver and intestines. Each of these metabolic disorders affect certain organs from functioning properly and therefore your overall healthiness.
Diabetes
Type 2 diabetes is one of the most common types of metabolic disorders in the world that is expected to affect 592 million people by 2035. It is characterised by high blood sugar, insulin resistance or a lack of insulin being produced by the pancreas. Insulin resistance occurs when the body isn’t able to use insulin the right way which increases blood glucose levels. Insulin is needed for cells to take in glucose (sugar) from the bloodstream and convert it into energy. Over time this lack of insulin can damage the organs in your body.
Metabolic Syndrome
Metabolic syndrome (also known as syndrome X, Reaven’s syndrome, and CHAOS) is not a disease but a collection of risk factors that affect your health; these include high blood pressure, high blood sugar/cholesterol and abdominal fat. Left untreated, these risk factors, together, can lead to long term serious problems including an increased risk of heart disease, stroke and developing type 2 diabetes.
Can you improve your metabolic health?
Yes! The good news is that if you discover that your metabolic health is not up to scratch you can improve it through a combination of diet, exercise and lifestyle adjustments such as:
- 30 minutes of moderate to intense exercise 5-7 times a week
- Low-dose aspirin to reduce your risk of stroke or heart attack
- Quit smoking
- Medication for blood pressure/cholesterol/ blood sugar
- Limit alcohol intake
- Eat a healthy balanced diet
Related Products
Randox has developed the RX series of clinical chemistry analysers for superior semi-automated and fully automated testing. The RX series extensive dedicated test menu goes beyond routine testing and has many unique and high-performance tests available. Our range of tests covers several parameters to assess your overall metabolic health.
Metabolic Health Profile
Albumin | Chloride | Potassium |
Alkaline Phosphatase | C02 Total | Sodium |
ALT | Creatinine | Total Bilirubin |
AST (GOT) | Glucose | Total Protein |
Direct Bilirubin | Lactate | Urea |
Calcium |
The RX series clinical chemistry analysers provide laboratories with a robust and smart solution ensuring you maintain a consistent workflow and can provide accurate results first time, every time. Offering excellent customer support services, our trained engineers are on hand to work with you in preserving the continuity of your operations while maximising the potential of your RX series instrument.Our world-famous test menu of high quality reagents ensures excellence in patient care, guaranteeing unrivalled precision and accuracy reducing costly test re-runs or misdiagnosis and offering complete confidence in results.
For more information visit: https://www.randox.com/clinical-chemistry-analysers/
How Randox is helping to diagnose metabolic conditions
Metabolic health is a term used to describe a collection of required chemical reactions that take place in all living organisms. A metabolic disorder develops when an abnormal chemical reaction occurs which alters the normal metabolic process.
A common misconception surrounding metabolic health is that it refers solely to your weight, and if you are overweight you are considered to be unhealthy. But in actual fact this may not be entirely true. Good metabolism means that your body is in good overall health, which doesn’t account for just your weight! Common metabolic disorders include genetic metabolic disorders, diabetes and metabolic syndrome. Understanding and testing to see how well your metabolism is functioning is key to ensuring long lasting health.
Genetics
There are a number of genetic metabolic disorders caused by mutations of single genes. Examples of common disorders include Gaucher’s disease, hemochromatosis and cystic fibrosis. Gaucher’s disease is a genetic disorder that affects the body’s ability to break down fat that can accumulate in the liver/spleen and bone marrow. Hemochromatosis is a condition that is caused by the over-absorption and build-up of iron while cystic fibrosis is a metabolic disorder that appears as a result of a build-up of mucus in lungs/liver and intestines. Each of these metabolic disorders affect certain organs from functioning properly and therefore your overall healthiness.
Diabetes
Type 2 diabetes is one of the most common types of metabolic disorders in the world that is expected to affect 592 million people by 2035. It is characterised by high blood sugar, insulin resistance or a lack of insulin being produced by the pancreas. Insulin resistance occurs when the body isn’t able to use insulin the right way which increases blood glucose levels. Insulin is needed for cells to take in glucose (sugar) from the bloodstream and convert it into energy. Over time this lack of insulin can damage the organs in your body.
Metabolic Syndrome
Metabolic syndrome (also known as syndrome X, Reaven’s syndrome, and CHAOS) is not a disease but a collection of risk factors that affect your health; these include high blood pressure, high blood sugar/cholesterol and abdominal fat. Left untreated, these risk factors, together, can lead to long term serious problems including an increased risk of heart disease, stroke and developing type 2 diabetes.
Can you improve your metabolic health?
Yes! The good news is that if you discover that your metabolic health is not up to scratch you can improve it through a combination of diet, exercise and lifestyle adjustments such as:
- 30 minutes of moderate to intense exercise 5-7 times a week
- Low-dose aspirin to reduce your risk of stroke or heart attack
- Quit smoking
- Medication for blood pressure/cholesterol/ blood sugar
- Limit alcohol intake
- Eat a healthy balanced diet
Related Products
Randox has developed the RX series of clinical chemistry analysers for superior semi-automated and fully automated testing. The RX series extensive dedicated test menu goes beyond routine testing and has many unique and high-performance tests available. Our range of tests covers several parameters to assess your overall metabolic health.
Metabolic Health Profile
Albumin | Chloride | Potassium |
Alkaline Phosphatase | C02 Total | Sodium |
ALT | Creatinine | Total Bilirubin |
AST (GOT) | Glucose | Total Protein |
Direct Bilirubin | Lactate | Urea |
Calcium |
The RX series clinical chemistry analysers provide laboratories with a robust and smart solution ensuring you maintain a consistent workflow and can provide accurate results first time, every time. Offering excellent customer support services, our trained engineers are on hand to work with you in preserving the continuity of your operations while maximising the potential of your RX series instrument. Our world-famous test menu of high quality reagents ensures excellence in patient care, guaranteeing unrivalled precision and accuracy reducing costly test re-runs or misdiagnosis and offering complete confidence in results.
For more information visit: https://www.randox.com/clinical-chemistry-analysers/
Product Spotlight: Liquid Lipid Control
Cardiovascular disease (CVD) is a general term for conditions affecting the heart or blood vessels. It is usually associated with a build-up of fatty deposits inside the arteries and increased risk of blood clots. It can be associated with damage to arteries in organs such as the brain, heart, kidney and eyes. Some types of CVD include coronary heart disease, strokes and aortic disease. Some of the main causes of CVD are smoking, high cholesterol, diabetes and high blood pressure (NHS, 2016).
These diseases can be extremely dangerous and lead to permanent damage or even death, therefore, it is vitally important for laboratories to be confident in their analyser’s ability to accurately diagnose and monitor the risk of these diseases.
The Randox Acusera Liquid Lipid quality control includes assayed target values and ranges for 8 analytes covering the complete lipid profile. With a 30 day open vial stability the Acusera Liquid Lipid control will reduce waste, whilst remaining easy and convenient to use. Three distinct levels are available covering low risk, borderline risk, and high risk concentrations of HDL and LDL cholesterol, ensuring the clinically relevant decision levels are tested, eliminating the need to purchase additional high and low level controls. Containing no Sodium Azide, which can interfere with direct clearance methods for detecting HDL and LDL cholesterol, ensuring ultimate accuracy and confidence in results.
Key Features & Benefits
- Liquid for ease of use
- 100% human serum
- Assayed target values provided
- True third party control
- Stable to expiry date at -20°C to -80°
- Open vial stability of 30 days at 2°C to 8°C
Analytes
Apolipoprotein A | Apolipoprotein B | Cholesterol (HDL) | Cholesterol (LDL)
Cholesterol (Total) | C-Reactive Protein (CRP) | Lipoprotein (a) | Triglycerides
HDL Cholesterol
High-Density Lipoproteins (HDL) are one of the major classes of plasma lipoproteins. HDL is often referred to as ‘good cholesterol’ because it transports cholesterol from the tissues of the liver for removal from the body. High levels of HDL can indicate a lower risk of developing heart disease.
Apolipoprotein A-1
Apolipoprotein A-1 is one of the main protein forms found in High Density Lipoproteins (HDL). The chief role of Apolipoprotein A-1 is in the activation of lecithin cholesterol acyltransferase (LCAT) and the capture and removal of free cholesterol from extra hepatic tissue. Studies have shown that there is an inverse relationship between Apolipoprotein A-1 and coronary artery disease (CAD).
References
NHS. (2016). Heart attack. nhs.uk. Retrieved 15 February 2018, from https://www.nhs.uk/conditions/heart-attack/
National Institute for Health and Care Excellence. (2014). Myocardial infarction (acute) Early rule out using high-sensitivity troponin tests. Nice.org.uk. Retrieved 15 February 2018, from https://www.nice.org.uk/guidance/dg15/chapter/3-clinical-need-and-practice
Protected: The Benefits of True Third Party Controls -New Test
Take control of your heart health with Randox
Your heart is amazing. Not only is it your most critical organ but also one of the most hard-working. The average adult heart beats around 100,000 times a day, acting as a giant pump for all the blood in your body. Indeed, every day your heart pumps over nine litres of blood through a system of blood vessels over 60,000 miles long – it’s little wonder, then, the importance placed on looking after such a vital muscle.
The heart works 24/7, only taking a rest when you sleep with the natural drop of heart rate and blood pressure. Over time, and influenced by lifestyle choices, the heart grows weaker, needing to work harder to fulfil its function. Crucial lifestyle changes now could limit your risk of developing serious cardiac conditions, such as Cardiovascular Disease (CVD) in the future. Factors which can contribute to your CVD risk include genes inherited from parents or grandparents, smoking, an unhealthy diet, excessive alcohol consumption and low physical activity levels.
You can’t change your DNA, but you can find out what it means to you and your family. One of our advanced tests can identify people living with a common but often hidden disorder – Familial Hypercholesterolemia (FH). Fewer than 12% of people in the UK know they have this potentially fatal condition. It is characterised by dangerously high levels of cholesterol which can lead to early onset cardiovascular disease.
While lifestyle changes may help to limit your risk of CVD, and related heart condition, it is impossible to eradicate it completely for everyone. Accounting for 31% of deaths worldwide, CVD is the number one cause of death globally but early screening could lower this figure significantly. That’s why it’s vitally important to detect CVD early before a coronary event like a heart attack occurs.
Today in the UK, 530 people will go to the hospital with a suspected heart attack. Only a fifth of these people will actually be having a heart attack. According to a team from King’s College London, as reported by the BBC, a faster, more accurate diagnosis of whether chest pain is caused by a heart attack would save the health service millions of pounds each year by sending well patients home and freeing up beds. Yet current testing methods do not efficiently differentiate between high-risk patients and the estimated 80% of patients who are not having a heart attack.
Randox’s revolutionary test for Heart-Type Fatty Acid-Binding Protein (H-FABP), when combined with current testing, is able to rule out a heart attack for patients who present at A&E with chest pain which is caused by other conditions such as respiratory issues, meaning they may not need emergency admission.
When measured at the time a patient presents to A&E with chest pain, H-FABP enables doctors to triage patients suffering with a heart attack more efficiently than before, making sure those at high-risk are given medical intervention earlier.
Early screening in the form of a comprehensive health check is essential to detect cardiac irregularities before they become serious problems. Heart damage builds up over time, meaning that when detected early enough, lifestyle changes can help to reduce cardiac risk and potentially even prevent a cardiac event occurring.
Therefore, it is vitally important that individuals are tested for CVD to detect them in the earliest stages to reduce damage, prevent further damage, or even death. Furthermore, many people suffer from inherited cardiac risk factors, which stresses the need for accurate testing.
Randox offer the complete laboratory solution to cardiac risk assessment information to doctors and hospitals, and also directly to the public at Randox Health. Our range of both traditional and novel cardiac risk biomarkers, along with our technologically-advanced range of analysers, serves to allow us to offer the most advanced, most accurate health check available on the planet.
As well as your cardiovascular risk score, a Randox Health check will also assess your cholesterol levels, FH risk, triglycerides, creative kinase, myoglobin, troponin levels and many more heart health indicators. In total, a Randox Health check can assess up to 350 different markers of irregularity or disease in the whole body, from heart to hormone health and skin to stomach.
Many serious future health issues are preventable now with action. Find out more about our health check programmes here.
About Randox Health
Randox Health is a global leader in healthcare diagnostics; today more than 5% of the world’s population – in excess of 370 million people across 145 countries – receives medical diagnosis using Randox products each year.
After investing over £220 million in the invention and production of revolutionary blood-science technology, a single Randox Health check will deliver a complete picture of your health – as it is now and, crucially, how it is likely to develop in the future.
Randox Health has proven that signs of disease or irregularity can be caught at their earliest stage. This means that, with early action, some cases of illness can even be prevented altogether. Our health checks include, but are not limited to, cancer surveillance, fertility monitoring, heart health, nutrition, digestive and diabetes health.
In other words, from one health check, you’ll receive up to 350 results and afterwards avail of expert advice from the Randox scientists or a Randox Health GP. Not only that, but a complete 12-month programme and repeat testing come as standard so you can have full confidence that you are really taking care of yourself.
Find out more information about Randox Health checks here: https://www.randoxhealth.com/our-packages/
RX Series
Randox has developed the RX series range of clinical chemistry analysers for high-quality semi-automated and fully automated testing. Choose between the RX misano, RX monaco, RX daytona+, RX imola, and the RX modena depending on the throughput of your laboratory. The RX series offers a suitable analyser for your laboratory’s needs. For more information on the Randox RX series, please click here or email therxseries@randox.com
Reagents
Randox offers an extensive range of third party diagnostic reagents which are internationally recognised as being of the highest quality; producing accurate and precise results. We have the largest test menu of 118 assays, covering over 100 disease markers including specific proteins, lipids, therapeutic drug monitoring, drugs of abuse, antioxidants, coagulation, diabetes and veterinary testing. A wide range of formats and methods are available providing greater flexibility and choice for any laboratory size. In addition to flexible pack sizes and a comprehensive list of analyser applications, we can also provide dedicated reagent packs (Randox Easy Read and Easy Fit regents) for a wide range of chemistry analysers providing you with freedom of choice from an independent manufacturer.
For more information on Randox Reagents, please click here or email reagents@randox.com
Acusera – Internal Quality Control
The Acusera cardiac controls have been designed to cover a wide range of cardiac markers at clinical decision levels, eliminating the extra expense of an additional low level control. The controls are available in a both liquid ready-to-use and lyophilized formats making them ideal for all situations and manufactured from 100% human serum a matrix similar to that of the patient is guaranteed. For more information on the Randox Acusera internal quality control, please click here or email acusera@randox.com
RIQAS – External Quality Control
The RIQAS Liquid Cardiac EQA programme is designed to monitor the performance of up to 9clinically significant cardiac markers including: CK-MB mass, D-dimer, Digoxin, homocysteine, hsCRP, myoglobin, NT proBNP, troponin I, and troponin T. RIQAS is ISO/IEC 17043 accredited and allows the registration of up to five instruments at no extra cost. All samples are 100% human serum and provided in a liquid ready-to-use format for enhanced convenience. Submit your results bi-weekly and view reports online via RIQAS.Net. For more information on RIQAS, the world’s largest international EQA scheme, please click here or email acusera@randox.com
For further information, please contact the Randox PR team via email: randoxpr@randox.com or phone 028 9442 2413
Product Spotlight: RIQAS CO-Oximetry EQA
RIQAS CO-Oximetry EQA
The RIQAS CO-Oximetry EQA Programme is a comprehensive programme suitable for monitoring the performance of 7 CO-Oximetry parameters. All samples are supplied in a liquid ready-to-use format ideal for both clinical and point-of-care testing (POCT).
Background
CO-Oximetry is a methodology that measures the levels of the oxygen-carrying protein haemoglobin, which is the chief component of red blood cells. CO-Oximetry is a useful tool in that it helps determine the levels of various forms of haemoglobin.
Key Benefits & Features
- Liquid ready-to-use
- Monthly reporting
- Submit results and view reports online via RIQAS.Net
- Suitable for POCT
Liquid ready-to-use
The liquid stable formulation requires no preparation making the samples extremely easy and convenient to use.
Consolidation
Covering 7 CO-Oximetry parameters, the RIQAS CO-Oximetry programme offers a streamlined approach to your EQA, allowing you to test your whole CO-Oximetry menu.
RIQAS
RIQAS is the largest international External Quality Assessment (EQA)/ Proficiency Testing (PT) scheme, there are currently more than 45,000 participants in 133 countries. World renowned for reducing the number of individual programmes required by even the most demanding laboratories.
Analytes
- Carboxyhaemoglobin (COHb / HbCO)
- Methaemoglobin (MetHb)
- Oxygen Content (O₂CT)
- Oxygen Saturation (sO₂ / Vol O₂)
- Oxyhaemoglobin (O₂Hb / HbO₂)
- Total Haemoglobin (tHb)
- Reduced / Deoxyhaemoglobin (RHb / HHb)
Related Products
RIQAS Blood Gas EQA
Suitable for monitoring the performance of 10 blood gas parameters.
- Accredited to ISO/IEC 17043
- Liquid ready-to-use
- Aqueous material
- Monthly reporting
- Submit results and view reports online via RIQAS.Net
- Suitable for POCT
Download some of our related brochures below and broaden your understanding.
References
Chatburn, R. (2014). To co-ox or not to co-ox. Acutecaretesting.org. Retrieved 19 February 2018, from https://acutecaretesting.org/en/articles/to-coox-or-not-to-coox
The Complete Solution to Cardiac Risk Assessment
“CVDs are the number 1 cause of death globally: more people die annually from CVDs than from any other cause”. In 2015, roughly 17.7 million people died from CVD, representing 31% of all global deaths: 7.4 million were due to coronary heart disease and 6.7 million were due to stroke. (WHO, 2017)
Cardiac health and regular cardiovascular screening is important to enable risk factors to be detected in their earliest stages. There are a few factors which contribute to CVD. These include: smoking, unhealthy diet, excessive alcohol consumption, low physical activity levels. Whilst there are only a few factors contributing to CVD, these can be maintained by the patient through living a healthy lifestyle including: quitting smoking, consuming no more than the recommended allowance of alcohol, cutting out junk food, and exercising for 30 minutes a day, 3 – 5 days a week. In a perfect world, this would be easy and CVD would not be a global problem. However, due to busy lifestyles, cravings, reduced willpower, and convenience, not all individuals in today’s world will be able to avoid CVDs. Therefore, it is vitally important that individuals are tested for CVDs to detect them in the earliest stages to reduce damage, prevent further damage, or even death. Furthermore, many individuals suffer from inherited cardiac risk factors, which stresses the need for accurate testing of both traditional and novel cardiac risk biomarkers.
Randox offer the complete solution to cardiac risk assessment including: RX analysers, traditional and novel reagents, internal quality control (Acusera), and external quality control (RIQAS).
RX Series
Randox has developed the RX series range of clinical chemistry analysers for high-quality semi-automated and fully automated testing. Choose between the RX misano, RX monaco, RX daytona+, RX imola, and the RX modena depending on the throughput of your laboratory. The RX series offers a suitable analyser for your laboratory’s needs. For more information on the Randox RX series, please click here or email therxseries@randox.com
Reagents
As previously mentioned, early assessment of cardiac risk is vital. Randox offer a range of novel risk biomarkers for both very early and the genetic assessment of cardiac risk.
LDL cholesterol is often referred to as the ‘bad cholesterol’. High concentrations of LDL-cholesterol is considered to be the most important clinical predictor, of all single parameters, with respect to coronary atherosclerosis. However, sLDL is a smaller, more dense subfraction of LDL-cholesterol. sLDL particles more readily permeate the inner arterial wall and are more susceptible to oxidation. Individuals with a predominance of sLDL have a 3-fold increased risk of myocardial infarction. Measurement of sLDL allows the clinician to get a more comprehensive picture of lipid risk factors and tailor treatment accordingly.
Elevated levels of Lp(a) are considered to be both a casual risk factor and independent genetic marker of atherosclerotic disorders. The major challenge associated with Lp(a) measurement is the size variation of apo(a) within Lp(a). Dependent upon the size of apo(a) in the assay calibrator, many assays under or overestimate apo(a) size in the patient sample. Numerous commercially available products suffer apo(a) size related bias, resulting in an over estimation of Lp(a) in samples with large apo(a)molecules and an under estimation in samples with small apo(a) molecules. The antibody used in the Randox method detects the complete Lp(a) molecule providing accurate and consistent results. This was proven by the IFCC who developed a gold standard ELISA reference assay and compared 22 commercially available tests. The Randox Lp(a) method displayed the least (minimal) amount of apo(a) size related bias, proving it be a superior offering.
HDL3 Cholesterol is a smaller and more dense subfraction of the HDL particle. HDL is the scavenger of cholesterol within arterial walls and the levels of HDL3 is too low, the ability to remove this cholesterol is reduced. Therefore, it is widely accepted that there is an inverse correlation between HDL3 and CVD risk.
Instrument Specific Applications (ISA’s) are available for a wide range of biochemistry analysers. Contact us to enquire about your specific analyser.
For more information on Randox Reagents, please click here or email reagents@randox.com
Acusera – Internal Quality Control
The Acusera cardiac controls have been designed to cover a wide range of cardiac markers at clinical decision levels, eliminating the extra expense of an additional low level control. The controls are available in a both liquid ready-to-use and lyophilized formats making them ideal for all situations and manufactured from 100% human serum a matrix similar to that of the patient is guaranteed. For more information on the Randox Acusera internal quality control, please click here or email acusera@randox.com
RIQAS – External Quality Control
The RIQAS Liquid Cardiac EQA programme is designed to monitor the performance of up to 9clinically significant cardiac markers including: CK-MB mass, D-dimer, Digoxin, homocysteine, hsCRP, myoglobin, NT proBNP, troponin I, and troponin T. RIQAS is ISO/IEC 17043 accredited and allows the registration of up to five instruments at no extra cost. All samples are 100% human serum and provided in a liquid ready-to-use format for enhanced convenience. Submit your results bi-weekly and view reports online via RIQAS.Net. For more information on RIQAS, the world’s largest international EQA scheme, please click here or email acusera@randox.com
For further information, please contact the Randox PR team via email: randoxpr@randox.com or phone 028 9442 2413
Reconstituting Lyophilised Controls
What is Lyophilisation?
Lyophilisation or ‘freeze drying’ is the process by which water is removed from a product after it is frozen and placed under a vacuum, allowing the ice to change directly from solid to vapor without passing through a liquid phase. The process consists of three separate processes:
- Freezing
- Primary Drying (Sublimation)
- Secondary Drying (Desorption)
There are many benefits to using a lyophilised control including; improved product shelf-life and enhanced stability of volatile analytes. For example, many lyophilised controls have a shelf life of up to four years from the date of manufacture resulting in a reduction of costly new lot validation studies. Furthermore, lyophilised controls can be aliquoted and refrozen to extend the working stability of the product.
Reconstituting Lyophilised QC Material
The process of reconstitution involves adding a specified volume of distilled water to lyophilised QC material. The water should completely dissolve the lyophilised contents, giving a liquid solution, which is ready for analysis.
Reconstitution is a straightforward process, but requires a high level of precision. Small errors can have serious implications to the reconstituted material:
- If too much water is pipetted during reconstitution, the material will be heavily diluted and results will be lower than expected
- If too little water is pipetted during reconstitution, the material will not be sufficiently diluted, and results will be higher than expected
- If the correct volume of water is pipetted, but a small amount of water gets stuck in the pipette tip due to poor pipetting technique, results will be higher than expected
If a lyophilised control has been reconstituted incorrectly the contents of the vial will be wasted. It is therefore vitally important that controls are reconstituted with care.
Materials and Methods Required
The list of requirements for an accurate and consistent reconstitution technique is not extensive, but each requirement is vital. Labs should have:
- Calibrated volumetric pipettes
- Sterile, appropriately sized pipette tips
- Distilled water, or other reconstitution fluid as specified
- Technician with good pipetting technique
- Lyophilised QC stored according to manufacturer’s specifications
How to Reconstitute Lyophilised QC Material
Each different lyophilised control may require slightly different preparation, always refer to the instructions for use before reconstituting control material. The below guide provides a general overview of the reconstitution process, using the Randox Human Assayed Chemistry Premium Plus control (HN1530) as an example
- Place the vial of lyophilised QC on a flat surface, carefully remove the lid and the rubber stopper making sure not to spill any material
- Using a calibrated pipette and sterilised pipette tip, add exactly 5ml of distilled water directly into the QC vial, ensuring no water is left in the pipette tip, or on the rim/side of the vial
- Place the rubber stopper and lid firmly back onto the QC vial, and leave to stand for 30 minutes
- After 30 minutes, gently invert the QC vial 10-15 times to ensure the contents is completely dissolved, making sure to avoid the formation of foam. It is important that you DO NOT SHAKE the vial. Alternatively place the vial on a roller for 30 minutes to ensure the contents is thoroughly mixed
- Once satisfied all material has been completely dissolved, proceed to use the QC product in accordance with the ‘Control’ section of the individual analyser application
- Once finished, refrigerate any unused material. It is good practice to label the vial with the date of reconstitution to prevent the use of material outside of the recommended stability period
- Prior to reusing lyophilised material, mix the contents thoroughly by gentle inversion, as highlighted in Step 4
Additional Considerations
It is important to remember that there may be slightly different reconstitution requirements for different QC material. For this reason, it is vital that the instructions provided on the QC Kit Inserts are closely followed.
Reconstituting lyophilised QC can be time-consuming. Therefore, Randox Acusera offer convenient 5ml distilled water serum diluent to assist laboratories with reconstitution of lyophilised controls. These user-friendly pour over vials streamline the reconstitution process and eliminate the risk of pipetting errors.
If you have any further questions regarding lyophilised controls or would like to contact us, please do so by emailing us at acusera@randox.com or use the contact us button provided.